Magnetic separation equipment and custom magnetic solutions
OSENC Magnetic Separation Request a Recommendation

Installation & Maintenance

How to Install a Suspended Magnet Above a Conveyor

 OSENC Magnetic Separation Position, Height and Commissioning Install a suspended magnet from the approved project drawing: confirm inline or crossbelt position, measure suspension height from the specified datum, verify the support structure and lifting points, remove harmful steel interference,

Self-Cleaning Overband Magnet Maintenance Guide

 OSENC Magnetic Separation Cleaning Belt, Drive and Discharge Maintain a self-cleaning overband by trending belt tracking, tension, splice or joint condition, cleats, rollers, bearings, drive, fasteners, guards, magnetic-face buildup, and iron discharge. Use the supplied manual for limits and

How to Install a Magnetic Head Pulley on a Conveyor

 OSENC Magnetic Separation Mechanical Interface and Separation Trajectory A magnetic head pulley is not a drop-in replacement until shaft ends, bearings, pulley diameter and face, belt speed and wrap, drive arrangement, loads, lagging, rotation, magnetic arc, discharge trajectory, splitter,

How to Adjust a Magnetic Drum Separator Splitter

 OSENC Magnetic Separation Feed, Trajectory and Fraction Quality Set the splitter only after feed distribution, drum rotation, speed, magnetic arc, material condition, and discharge flow are stable. Observe where magnetic and nonmagnetic particles actually leave the drum, position the

How to Inspect and Test a Magnetic Tube

 OSENC Magnetic Separation Incoming, Routine and Replacement Checks Inspect a magnetic tube by checking traceable identity, dimensions, effective magnetic length, surface and weld condition, end fittings, cleanliness, and a magnetic measurement made at defined positions with a specified instrument

How to Clean a Magnetic Grate Without Losing Control of Captured Iron

 OSENC Magnetic Separation Cleaning Frequency, Safety and Records Clean a magnetic grate before accumulated iron or product buildup creates an excessive working gap, blocks flow, damages the surface, or releases contamination back into the process. Isolate the system, control